FTXM50N2V1B / RZAG35A2V1B FTXM35N2V1B / RZAG35A2V1B FTXM60N2V1B / RZAG50A2V1B FTXM50N2V1B / RZAG50A2V1B FTXM71N2V1B / RZAG60A2V1B FTXM60N2V1B / RZAG60A2V1B
Indoor unit FTXM50N2V1B FTXM35N2V1B FTXM60N2V1B FTXM50N2V1B FTXM71N2V1B FTXM60N2V1B
Outdoor unit RZAG35A2V1B RZAG35A2V1B RZAG50A2V1B RZAG50A2V1B RZAG60A2V1B RZAG60A2V1B
Cooling capacity Min. kW 1.60 1.6 1.70 1.7 1.70 1.7
  Min. Btu/h 5,500 5,500.0 5,800 5,800.0 5,800 5,800.0
  Min. kcal/h 1,376 1,376.0 1,462 1,462.0 1,462 1,462.0
  Nom. kW 3.50 3.5 5.00 5.0 6.00 6.0
  Nom. Btu/h 11,900 11,900.0 17,100 17,100.0 20,500 20,500.0
  Nom. kcal/h 3,009 3,009.0 4,299 4,299.0 5,159 5,159.0
  Max. kW 5.00 5.0 6.00 6.0 6.80 6.8
  Max. Btu/h 17,100 17,000.0 20,500 20,500.0 23,200 23,200.0
  Max. kcal/h 4,299 4,299.0 5,159 5,159.0 5,847 5,847.0
Heating capacity Min. kW 1.40 1.40 1.50 1.50 1.60 1.60
  Min. Btu/h 4,800 4,780.0 5,100 5,100.0 5,500 5,500.0
  Min. kcal/h 1,200 1,200.0 1,300 1,290.0 1,400 1,380.0
  Nom. kW 4.00 4.00 6.00 6.00 7.00 7.00
  Nom. Btu/h 13,600 13,700.0 20,500 20,500.0 23,900 23,900.0
  Nom. kcal/h 3,439 3,439.0 5,159 5,159.0 6,019 6,019.0
  Max. kW 5.30 5.30 6.50 6.50 7.50 7.50
  Max. Btu/h 18,100 18,000.0 22,200 22,200.0 25,600 25,590.0
  Max. kcal/h 4,557 4,557.0 5,589 5,589.0 6,449 6,449.0
Power input Cooling Nom. kW 0.81 0.81 1.24 1.25 1.71 1.71
  Heating Nom. kW 1.02 1.04 1.47 1.50 1.90 1.94
Nominal efficiency EER   4.32 4.30 4.04 4.00 3.50 3.50
  COP   3.93 3.85 4.08 4.00 3.68 3.61
  Annual energy consumption kWh 405 407 619 625 857 857
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Space cooling Energy efficiency class   A++ A++ A++ A++ A++ A++
  Capacity Pdesign kW 3.50 3.50 5.00 5.00 6.00 6.00
  SEER   7.76 7.70 7.53 7.41 6.90 6.90
  Annual energy consumption kWh/a 158 159 232 236 304 304
  A Condition (35°C - 27/19) Pdc kW 3.50 3.50 5.00 5.00 6.00 6.00
    EERd   4.32 4.30 4.04 4.00 3.50 3.50
    Power input kW 0.81 0.81 1.24 1.25 1.71 1.71
  B Condition (30°C - 27/19) Pdc kW 2.58 2.58 3.68 3.68 4.42 4.42
    EERd   6.15 6.09 5.49 5.38 4.82 4.82
    Power input kW 0.42 0.42 0.67 0.68 0.92 0.92
  C Condition (25°C - 27/19) Pdc kW 1.80 1.80 2.37 2.37 2.84 2.84
    EERd   9.43 9.34 8.99 8.82 8.15 8.15
    Power input kW 0.19 0.19 0.26 0.27 0.35 0.35
  D Condition (20°C - 27/19) Pdc kW 1.89 1.91 2.10 2.08 2.10 2.10
    EERd   12.41 12.34 13.16 13.03 12.96 12.96
    Power input kW 0.15 0.15 0.16 0.16 0.16 0.16
Space heating (Average climate) Energy efficiency class   A++ A++ A++ A++ A+ A+
  Capacity Pdesign kW 2.60 2.60 4.50 4.50 4.50 4.60
  SCOP/A   4.68 4.60 4.69 4.60 4.40 4.35
  SCOPnet/A   4.70 4.63 4.73 4.64 4.43 4.38
  Pdh Heating capacity at -10° kW 2.47 2.47 3.89 3.89 3.95 4.02
  Annual energy consumption kWh/a 778 790 1,344 1,369 1,433 1,480
  Required back up heating cap at design conditions kW 0.13 0.13 0.61 0.61 0.55 0.58
  TOL Tol (temperature operating limit) °C -20 -20 -20 -20 -20 -20
    Pdh (declared heating cap) kW 3.03 3.03 3.61 3.61 3.85 3.85
    COPd (declared COP)   2.37 2.35 2.31 2.29 2.24 2.22
    Power input kW 1.28 1.29 1.56 1.58 1.72 1.73
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7 -7 -7
    Pdh (declared heating cap) kW 2.30 2.31 3.98 3.98 4.07 4.07
    COPd (declared COP)   3.06 3.00 3.06 3.00 2.77 2.74
    Power input kW 0.75 0.77 1.30 1.33 1.47 1.49
  A Condition (-7°C) Pdh (declared heating cap) kW 2.30 2.31 3.98 3.98 4.07 4.07
    COPd (declared COP)   3.06 3.00 3.06 3.00 2.77 2.74
    Power input kW 0.75 0.77 1.30 1.33 1.47 1.49
  B Condition (2°C) Pdh (declared heating cap) kW 1.40 1.35 2.42 2.44 2.48 2.48
    COPd (declared COP)   4.76 4.67 4.58 4.49 4.31 4.27
    Power input kW 0.29 0.29 0.53 0.54 0.58 0.58
  C Condition (7°C) Pdh (declared heating cap) kW 1.42 1.31 1.56 1.56 1.59 1.59
    COPd (declared COP)   6.25 6.13 6.12 6.00 5.77 5.71
    Power input kW 0.23 0.21 0.25 0.26 0.28 0.28
  D Condition (12°C) Pdh (declared heating cap) kW 1.66 1.54 1.67 1.67 1.67 1.67
    COPd (declared COP)   7.58 7.43 7.84 7.76 7.58 7.50
    Power input kW 0.22 0.21 0.21 0.22 0.22 0.22
Power consumption in other than active mode Crankcase heater mode Cooling PCK kW 0.000 0.000 0.000 0.000 0.000 0.000
    Heating PCK kW 0.000 0.000 0.000 0.000 0.000 0.000
  Off mode Cooling POFF kW 0.001 0.001 0.001 0.001 0.001 0.001
    Heating POFF kW 0.001 0.001 0.001 0.001 0.001 0.001
  Standby mode Cooling PSB kW 0.001 0.001 0.001 0.001 0.001 0.001
    Heating PSB kW 0.001 0.001 0.001 0.001 0.001 0.001
  Thermostat-off mode Cooling PTO kW 0.012 0.012 0.012 0.012 0.012 0.012
    Heating PTO kW 0.013 0.013 0.013 0.013 0.013 0.013
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes Yes
Cold season included No No No No No No
Warm season included No No No No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 62 62 63 63 64 64
  Sound power level indoor Cooling Nom. dBA 58 58 60 58 62 60
  Piping length Cooling Measuring condition m 5.00 5.0 5.00 5.0 5.00 5.0