FTXM20N2V1B / RXM20M3V1B9 |
FTXM25N2V1B / RXM25M3V1B9 |
FTXM35N2V1B / RXM35M3V1B9 |
Cooling capacity
|
Min.
|
kW
|
1.3
|
1.3
|
1.4
|
|
Max.
|
kW
|
2.6
|
3.2
|
4.0
|
|
Nom.
|
kW
|
2.0
|
2.5
|
3.4
|
Space cooling
|
SEER
|
|
8.53
|
8.52
|
8.51
|
|
Annual energy consumption
|
kWh/a
|
83
|
103
|
140
|
|
Capacity
|
Pdesign
|
kW
|
2.00
|
2.50
|
3.40
|
|
Energy efficiency class
|
|
A+++
|
A+++
|
A+++
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
2.30
|
2.40
|
2.50
|
|
SCOP/A
|
|
5.10
|
5.10
|
5.10
|
|
Energy efficiency class
|
|
A+++
|
A+++
|
A+++
|
|
Pdh Heating capacity at -10°
|
kW
|
2.24
|
2.30
|
2.35
|
|
Annual energy consumption
|
kWh/a
|
632
|
659
|
686
|
Nominal efficiency
|
Annual energy consumption
|
kWh
|
220
|
280
|
400
|
|
EER
|
|
4.57
|
4.50
|
4.23
|
|
COP
|
|
5.00
|
5.00
|
4.04
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
A
|
|
|
Heating
|
|
A
|
A
|
A
|
Heating capacity
|
Nom.
|
kW
|
2.50
|
2.80
|
4.00
|
|
Min.
|
kW
|
1.30
|
1.30
|
1.40
|
|
Max.
|
kW
|
3.50
|
4.70
|
5.20
|
Notes
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
|
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|