Specifications Table for FWC-BT

FWC06B5TV1B FWC07B5TV1B FWC08B5TV1B FWC09B5TV1B
Sound pressure level Low dBA 21.0 22.0 24.0 28.0
  High dBA 29.0 33.0 39.0 43.0
Standard Accessories Installation and operation manual 1 1 1 1
  Installation guide 1 1 1 1
  Drain hose 1 1 1 1
  Metal clamp for drain hose 1 1 1 1
  Washer for hanger bracket 8 8 8 8
  Screws 4 4 4 4
  O ring 2 2 2 2
  Insulation 4 4 4 4
Total sound power level Low dBA 31.0 33.0 36.0 40.0
  High dBA 43.0 47.0 53.0 57.0
Water flow Water pressure drop Heating High kPa 17 22 29 37
    Cooling High kPa 15 18 24 30
Piping connections Drain OD mm VP25 (External dia.32, internal dia. 25) VP25 (External dia.32, internal dia. 25) VP25 (External dia.32, internal dia. 25) VP25 (External dia.32, internal dia. 25)
  Water Inlet   3/4" BSP (female thread) 3/4" BSP (female thread) 3/4" BSP (female thread) 3/4" BSP (female thread)
    Outlet   3/4" BSP (female thread) 3/4" BSP (female thread) 3/4" BSP (female thread) 3/4" BSP (female thread)
Power input High kW 0.045 0.054 0.077 0.107
  Low kW 0.034 0.037 0.039 0.045
Allowed water temperature Heating Max. °C 50 (4) 50 (4) 50 (4) 50 (4)
    Min. °C 5 (4) 5 (4) 5 (4) 5 (4)
  Cooling Min. °C 5 (4) 5 (4) 5 (4) 5 (4)
    Max. °C 50 (4) 50 (4) 50 (4) 50 (4)
Dimensions Unit Width mm 840 840 840 840
    Depth mm 840 840 840 840
    Height mm 288 288 288 288
Weight Unit kg 26 26 26 26
Fan Air flow rate Low m³/h 720 834 888 1,044
    High m³/h 1,068 1,236 1,518 1,776
Cooling capacity (standard conditions) Sensible capacity 2-pipe Low kW 2.8 (1) 3.3 (1) 3.5 (1) 4.1 (1)
    High kW 4.2 (1) 4.7 (1) 5.7 (1) 6.5 (1)
  Total capacity 2-pipe Low kW 3.9 (1) 4.5 (1) 4.8 (1) 5.4 (1)
    High kW 5.5 (1) 6.1 (1) 7.2 (1) 8.1 (1)
Heating capacity (standard conditions) Capacity 2-pipe High kW 6.8 (2) 7.7 (2) 9.2 (2) 10.6 (2)
    Low kW 4.8 (2) 5.5 (2) 5.8 (2) 7.0 (2)
Power supply Phase   1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240
Notes (1) - Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C (1) - Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C (1) - Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C (1) - Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C
  (2) - Heating: 2 pipe: air 20°CDB, 15°CWB; entering water 45°C; leaving water 40°C (2) - Heating: 2 pipe: air 20°CDB, 15°CWB; entering water 45°C; leaving water 40°C (2) - Heating: 2 pipe: air 20°CDB, 15°CWB; entering water 45°C; leaving water 40°C (2) - Heating: 2 pipe: air 20°CDB, 15°CWB; entering water 45°C; leaving water 40°C
  (3) - Heating: 4 pipe: air 20°CDB, 15°CWB; entering water 65°C; leaving water 55°C (3) - Heating: 4 pipe: air 20°CDB, 15°CWB; entering water 65°C; leaving water 55°C (3) - Heating: 4 pipe: air 20°CDB, 15°CWB; entering water 65°C; leaving water 55°C (3) - Heating: 4 pipe: air 20°CDB, 15°CWB; entering water 65°C; leaving water 55°C
  (4) - Do not let water of less than 5°C or more than 50°/70°C enter the unit, this may damage the unit (4) - Do not let water of less than 5°C or more than 50°/70°C enter the unit, this may damage the unit (4) - Do not let water of less than 5°C or more than 50°/70°C enter the unit, this may damage the unit (4) - Do not let water of less than 5°C or more than 50°/70°C enter the unit, this may damage the unit