| FXMA50A5VEB | FXMA63A5VEB | FXMA80A5VEB | FXMA100A5VEB | FXMA125A5VEB | FXMA200AXVMB | FXMA250AXVMB | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Total capacity | At high fan speed | kW | 5.6 | 7.1 | 9.0 | 11.2 | 14.0 | 22.4 | 28.0 | |
| Heating capacity | Total capacity | At high fan speed | kW | 6.3 | 8.0 | 10.0 | 12.5 | 16.0 | 25.0 | 31.5 | |
| Power input - 50Hz | Cooling | At high fan speed | kW | 0.125 | 0.140 | 0.198 | 0.191 | 0.254 | 0.54 | 0.65 | |
| Heating | At high fan speed | kW | 0.125 | 0.140 | 0.198 | 0.191 | 0.254 | 0.54 | 0.65 | ||
| Dimensions | Unit | Height | mm | 300 | 300 | 300 | 300 | 300 | 470 | 470 | |
| Width | mm | 1000 | 1000 | 1000 | 1400 | 1400 | 1490 | 1490 | |||
| Depth | mm | 700 | 700 | 700 | 700 | 700 | 1100 | 1100 | |||
| Weight | Unit | kg | 35 | 35 | 35 | 46 | 46 | 105 | 115 | ||
| Casing | Colour | Unpainted | Unpainted | Unpainted | Unpainted | Unpainted | Unpainted | Unpainted | |||
| Material | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | ||||
| Required ceiling void > | mm | 350 | 350 | 350 | 350 | 350 | |||||
| Fan | Air flow rate - 50Hz | Cooling | At high fan speed | m³/min | 18.0 | 19.5 | 25.0 | 32.0 | 36.0 | 62 | 74 |
| At low fan speed | m³/min | 15.0 | 16.0 | 20.0 | 23.0 | 26.0 | 41 | 52 | |||
| External static pressure - 50Hz | High | Pa | 200 | 200 | 200 | 200 | 200 | 250 | 250 | ||
| Low | Pa | 50 | 50 | ||||||||
| External static pressure - 60Hz | High | Pa | 200 | 200 | 200 | 200 | 200 | 250 | 250 | ||
| Low | Pa | 50 | 50 | ||||||||
| Refrigerant | Type | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | |||
| GWP | 675 | 675 | 675 | 675 | 675 | 675 | 675 | ||||
| Sound power level | Cooling | At high fan speed | dBA | 61.0 | 64.0 | 67.0 | 65.0 | 70.0 | 75.0 | 76.0 | |
| Sound pressure level | Cooling | At high fan speed | dBA | 41.0 | 42.0 | 43.0 | 43.0 | 44.0 | 48.0 | 48.0 | |
| At medium fan speed | dBA | 39.0 | 40.0 | 41.0 | 41.0 | 42.0 | 46.5 | 46.5 | |||
| At low fan speed | dBA | 37.0 | 38.0 | 39.0 | 39.0 | 40.0 | 45.0 | 45.0 | |||
| Heating | At high fan speed | dBA | 41.0 | 42.0 | 43.0 | 43.0 | 44.0 | 48.0 | 48.0 | ||
| At medium fan speed | dBA | 39.0 | 40.0 | 41.0 | 41.0 | 42.0 | 46.5 | 46.5 | |||
| At low fan speed | dBA | 37.0 | 38.0 | 39.0 | 39.0 | 40.0 | 45.0 | 45.0 | |||
| Piping connections | Liquid | Type | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | ||
| OD | mm | 6.35 | 6.35 | 6.35 | 9.52 | 9.52 | 9.5 | 9.5 | |||
| Gas | Type | Flare connection | Flare connection | Flare connection | Flare connection | Flare connection | Flange | Flange | |||
| OD | mm | 12.7 | 12.7 | 12.7 | 15.9 | 15.9 | 19.1 | 19.1 | |||
| Drain | VP25 (I.D. 25/O.D. 32) | VP25 (I.D. 25/O.D. 32) | VP25 (I.D. 25/O.D. 32) | VP25 (I.D. 25/O.D. 32) | VP25 (I.D. 25/O.D. 32) | BSP1 | BSP1 | ||||
| Air filter | Type | Resin net | Resin net | Resin net | Resin net | Resin net | |||||
| Standard Accessories | General safety precautions | 1 | 1 | ||||||||
| Wire clamp material | 1 | 1 | |||||||||
| Spring washer | 2 | 2 | |||||||||
| Hexagon head screw | 2 | 2 | |||||||||
| Plain washer | 8 | 8 | |||||||||
| Hexagon head screw with washer | 49 | 49 | |||||||||
| Gas connection pipe | 1 | 1 | |||||||||
| Installation and operation manual | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| Power supply | Name | VE | VE | VE | VE | VE | VM | VM | |||
| Phase | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | ||||
| Frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | |||
| Voltage | V | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220-230 | 220-240/220-230 | |||
| Current - 50Hz | Maximum fuse amps (MFA) | A | 6 | 6 | 6 | 6 | 6 | 6 | 6 | ||
| Standard Accessories | Washer for hanger bracket | 8 | 8 | 8 | 8 | 8 | |||||
| Drain hose | 1 | 1 | 1 | 1 | 1 | ||||||
| Insulation for fitting | 2 | 2 | 2 | 2 | 2 | ||||||
| Metal clamp for drain hose | 1 | 1 | 1 | 1 | 1 | ||||||
| Screws | 16 | 16 | 16 | 16 | 16 | ||||||
| Sealing pad | 3 | 3 | 3 | 3 | 3 | ||||||
| Notes | (1) - Values are valid for the factory setting. | (1) - Values are valid for the factory setting. | (1) - Values are valid for the factory setting. | (1) - Values are valid for the factory setting. | (1) - Values are valid for the factory setting. | ||||||
| (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | |||||||
| (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m | |||||||
| (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | (4) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. | |||||||
| (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) | (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) | (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) | (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) | (5) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual) | |||||||
| (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | |||||||
| (7) - Maximum allowable voltage range variation between phases is 2%. | (7) - Maximum allowable voltage range variation between phases is 2%. | (7) - Maximum allowable voltage range variation between phases is 2%. | (7) - Maximum allowable voltage range variation between phases is 2%. | (7) - Maximum allowable voltage range variation between phases is 2%. | |||||||
| (8) - MCA/MFA: MCA = 1.1 x FLA | (8) - MCA/MFA: MCA = 1.1 x FLA | (8) - MCA/MFA: MCA = 1.1 x FLA | (8) - MCA/MFA: MCA = 1.1 x FLA | (8) - MCA/MFA: MCA = 1.1 x FLA | |||||||
| (9) - Instead of a fuse, use a circuit breaker | (9) - Instead of a fuse, use a circuit breaker | (9) - Instead of a fuse, use a circuit breaker | (9) - Instead of a fuse, use a circuit breaker | (9) - Instead of a fuse, use a circuit breaker | |||||||
| (10) - Select wire size based on the value of MCA | (10) - Select wire size based on the value of MCA | (10) - Select wire size based on the value of MCA | (10) - Select wire size based on the value of MCA | (10) - Select wire size based on the value of MCA | |||||||
| (11) - Contains fluorinated greenhouse gases | (11) - Contains fluorinated greenhouse gases | (11) - Contains fluorinated greenhouse gases | (11) - Contains fluorinated greenhouse gases | (11) - Contains fluorinated greenhouse gases | |||||||